#2. Hot air fault light illuminates on the air conditioning panel,
#3. Does the trim air provide the warm air or the cold air to the air conditioning system?
#4. In case of zone controller primary and secondary channel failure, what temperatures are maintained by pack one and pack two?
#5. In normal flight in closed circuit configuration, the avionics ventilation system controls the temperature of the cooling air by:
#6. To enable Ram air to the mixture unit, The Ram air switch should be used:
#7. Pack controller, primary channel failure.
#8. Pack controller, secondary channel failure
#9. Pack controller, primary and secondary channel failure
#10. Hot air press. reg. valve failed open
#11. Bleed air supplied from the APU (APU bleed valve open), the pack flow is automatically selected:
#12. Trim air valve, each one optimizes the temperature by:
#13. Hot air pressure regulating valve:
#14. Pack flow control valve:
#15. Engine flow demand, when the heating or cooling demand in one zone cannot be satisfied:
#16. What is the Norm.Max. cabin altitude?
#17. What is the Max. negative Diff. pressure for the cabin?
#18. It is permissible to use simultaneously packs and Lp ground unit during long stops in a hot airfield
#19. What are the different sources of air for air conditioning and pressurization?
#20. During the exterior preflight on a warm day, in what position would you expect to find the avionics ventilation system INLET and EXTRACT valves to be in?
#21. What happens to the pack flow control valves during engine start?
#22. The temperature of each aircraft zone is optimized by means of:
#23. When does normal pressurization occur?
#24. When does normal depressurization occur?
#25. Under what conditions should the pack flow controller be set to LO?
#26. Which statement is correct regarding illumination of the amber AFT ISOL VALVE fault light?
#28. What computers control the cabin and cockpit conditioned air?
#29. When would you select RAM AIR ON?
#30. What happens when a temperature selector rotary knob is adjusted?
#31. With APU BLEED ON and engine BLEED switches ON with engines running, what is the position of the engine bleed valves?
#32. Pressurization is normally automatic. Can you interfere with it?
#33. Under what conditions should the pack flow controller be set to HI?
#34. What is the function of the ram air valve?
#35. Placing the EXTRACT push button to override:
#36. The Ram Air valve:
#37. With the pressurization system in the automatic mode, which valves are closed when the ditching push button is selected on?
#38. What is the maximum negative differential pressure for the cabin?
#39. The HOT AIR valve push button controls:
#40. Both pressurization auto controllers are set by the active flight plan loaded in the MCDU. The QNH entry on the MCDU Approach Performance page refines the depressurization schedule for the landing.
#41. Aft cargo indications may be found on which ECAM page(s)?
#42. Avionics ventilation system indications may be found on which ECAM page(s)?
#43. When APU is supplying the packs, the pack controller sends a demand signal to increase airflow when a zone temperature cannot be satisfied. This signal is sent to the:
#44. In case of zone controller primary and secondary channel failure, what temperatures are maintained by Packs 1 and 2?
#45. The PACK FLOW controller is set to NORM and yet the ECAM display shows PACK FLOW to be high. How is this possible?
#46. When would you select PACK FLOW to HI?
#47. Which of the following statements is correct concerning conditioned air?
#48. How many temperature selectors are there on the A320? How many temperature zones are there?
#49. The temperature selectors are located in:
#50. During normal flight, the avionics ventilation system controls the temperature of the cooling air by:
#51. Placing the avionics ventilation system in the smoke configuration:
#52. How can you change controllers during flight?
#53. Hot air “FAULT” light illuminates on the air conditioning panel.
#54. How many trim air valves are there?
#55. How many trim air valves are there?
#56. What position do the pack valves go to in the event of a loss of the bleed system pressure?
#57. The RAM AIR switch should be used:
#58. What is the function of the Pack Flow selector?
#59. Which configuration is the avionics ventilation system in while airborne with no abnormals present?
#60. What is the maximum altitude associated with the pressurization system?
#61. Trim air valves are controlled by:
#62. Which statement is TRUE concerning the cargo compartment ventilation?
#63. The APU BLEED FAULT indicates that the main APU controller is in fault.
#64. Aft cargo ventilation is controlled by:
#65. The vent fan runs any time there is a normal ships power and the isolation valves are open.
#66. The cabin zone temperature sensors are ventilated by the air extracted by the lavatory and galley fans.
#67. Placing the BLOWER push button to override:
#68. Pressurization indications are found on which ECAM page(s)?
#69. How many outflow valves are there?
#70. At what cabin altitude do you get an ECAM warning?
#71. When the pack flow control knob is positioned to HI, air flow is:
#72. If you select a position other than the AUTO detent on the LDG ELEV AUTO selector, how can you see the actual landing elevation value?
#73. What will cause the ENG BLEED fault light to come on?
#74. What does the CARGO HEAT HOT AIR FAULT light indicate?
#75. During Ground function operation, the outflow valve is:
#76. The outflow valve is powered by:
#77. The purpose of the safety valve is to avoid:
#78. When landing elevation is set to AUTO, the landing elevation is sent to the controller from:
#79. The mixing unit is connected to:
#80. Once set to “ON” the air conditioning packs operate:
#81. Emergency ram air inlet. When set to “ON” the ram air valve will open and supply airflow:
#82. Cond. Zone regulator fault (primary channel failed):
#83. Temperature control is automatic and is regulated by:
#84. If a pack controller fails (primary and secondary channel failure), the pack outlet air temperature is controlled by:
#85. The zone controller optimizes temperature by action on:
#86. When using APU bleed to supply the packs, with the pack flow selector at LO, the pack airflow is:
#87. The pack flow control valve closed automatically in case of:
#88. In case of trim air system fault (zone controller primary channel failure), the secondary channel of the zone controller regulated the zone temperature at:
#89. In case of total zone controller failure:
#90. During landing run, Ram Air Inlet flaps open when speed is less than:
#91. The ditching switch when selected sends a closure signal to:
#92. In flight with pressure controller 1 in use, if it fails:
#93. In normal operation, pressurization is:
#94. During ground function operation, the outflow valve is:
#95. To see the operation of the outflow valve, it is necessary to call ECAM:
#96. Two identical, independent, automatic digital pressurization controllers are used for system control:
#97. Which controller generates excess cabin altitude and pressure signals for ECAM indication in manual mode:
#98. The safety valves are operated:
#99. The purpose of the safety valves is to avoid:
#100. When mode selector is selected to manual, the outflow valve is controlled by signals sent via controller 1 or 2
#101. On ECAM Cab. press page, the outflow valve indicator changes to amber if:
#102. On ECAM Cab. press page, the safety valve indication changes to amber if:
#103. On ECAM Cab. press page, the cabin altitude indication changes to red when cabin altitude is:
#104. Following a system 1 fault:
#105. The pressure safety valve opens at:
#106. After the engine start, the Pack Flow Control Valves automatically open, however on the ground, reopening of the valves is delayed for _____ after the first engine start.
#107. The Ram Air Inlet Flaps remain open during takeoff and landing to allow extra airflow during high power situations.
#108. The temperature of the air that exits the compressor section is displayed above the Pack Flow. It normally displays green, but displays amber for temperatures over:
#109. The trim air valves are _____ controlled by the zone controller
#110. The avionics ventilation system is not capable of using external air to provide cooling airflow
#111. During flight below _____, the Ram Air Valve can provide an emergency source of conditioned air during non-pressurized flight.